Artykuł w czasopiśmie
Brak miniatury
Licencja

ClosedAccessDostęp zamknięty

Limits in measurements of contact lens surface profile using atomic force microscopy

Autor
Brygoła, Rafał
Kowalczyk-Hernandez, Marek
Sokołowski, Maciej
Pniewski, Jacek
Sęk, Sławomir
Data publikacji
2018
Abstrakt (EN)

In the paper the results of AFM surface profile measurements of seven new long-wear contact lenses (CL) available in Poland are presented. Calculated statistical roughness parameters are shown, namely standard deviation (RMS), mean roughness, maximum difference between peak and valley, skewness, and kurtosis. It is demonstrated that CLs manufactured using recent methods, such as two-stage polimerisation or extending silicon chains exhibit small RMS, less than 10 nm, in comparison with older generation CLs which maintains RMS on the level of tens of nanometers. Then, a comparison of results obtained using a typical silicon tip and a silicon tip covered with alkylsilane is also demonstrated. As a result, roughness parameters, such as RMS, are higher for the case of alkylsilane-coated tip than for a typical silicon tip, 8.39 ± 0.16 nm vs. 6.22 ± 0.9 nm, which leads to the conclusion that the proper choice of the tip material significantly influences the outcome of the experiment. Finally, the reliability and limits of such measurements are discussed

Słowa kluczowe EN
Atomic force microscopy
Contact lenses
Roughness
Topography
Dyscyplina PBN
nauki chemiczne
Czasopismo
Colloids and Surfaces B: Biointerfaces
Tom
165
Strony od-do
229-234
ISSN
0927-7765
Licencja otwartego dostępu
Dostęp zamknięty