Artykuł w czasopiśmie
Brak miniatury
Licencja

ClosedAccessDostęp zamknięty
 

Point-of-care testing for C-reactive protein in a sequential microfluidic device

Uproszczony widok
cris.lastimport.scopus2024-02-12T20:25:57Z
dc.abstract.enPoint-of-care testing (POCT) devices are currently available for the detection of various important diseases owing to their easy-to-use, portable, and user-friendly nature. However, the multistep regent manipulation still impedes the performance of the device for end-users. To address this issue, we present a novel sequential flow-through microfluidic device that incorporates dual flow behaviors (fast-flow/delayed) into a single device for assessing the risk of cardiovascular disease (CVDs) using C-reactive protein (CRP) as the model analyte. The device features a fast-flow channel for automated washing of unbound CRP antigens and a delayed channel for flow of a redox reagent for electrochemical analysis. It requires only a single buffer loading, resulting in a total analysis time of 15 min. To overcome challenges related to storage stability and the affinity of antibodies in the manufacturing process, we integrated the P3-CRP peptide as a new bioreceptor for CRP detection. The performance of both the P3-CRP peptide and antibodies was assessed and examined using chronocoulometry. The proposed device exhibited a limit of detection at 47 pg mL−1 with a wide linear range (5 orders of magnitude). To validate its applicability, the device was tested with serum, plasma, and whole blood samples, yielding satisfactory results.
dc.affiliationUniwersytet Warszawski
dc.contributor.authorJönsson-Niedziółka, Martin
dc.contributor.authorPałys, Barbara
dc.contributor.authorNiedziółka-Jönsson, Joanna
dc.contributor.authorSzot-Karpińska, Katarzyna
dc.contributor.authorBoonkaew, Suchanat
dc.date.accessioned2024-01-25T17:00:07Z
dc.date.available2024-01-25T17:00:07Z
dc.date.issued2023
dc.description.financeNie dotyczy
dc.description.volume397
dc.identifier.doi10.1016/J.SNB.2023.134659
dc.identifier.issn0925-4005
dc.identifier.urihttps://repozytorium.uw.edu.pl//handle/item/116166
dc.identifier.weblinkhttps://api.elsevier.com/content/article/PII:S0925400523013746?httpAccept=text/xml
dc.languageeng
dc.pbn.affiliationchemical sciences
dc.relation.ispartofSensors and Actuators, B: Chemical
dc.relation.pages134659
dc.rightsClosedAccess
dc.sciencecloudnosend
dc.subject.enC-reactive protein
dc.subject.enPoint-of-care testing
dc.subject.enPeptide
dc.subject.enCapillary-driven microfluidic device
dc.subject.enLabel-free immunoassay
dc.subject.enElectrochemical detection
dc.titlePoint-of-care testing for C-reactive protein in a sequential microfluidic device
dc.typeJournalArticle
dspace.entity.typePublication