Artykuł w czasopiśmie
Brak miniatury
Licencja

ClosedAccessDostęp zamknięty
 

Fluorimetric Readout of Ion Selective Electrode Signals Operating under Chronopotentiometric Conditions

cris.lastimport.scopus2024-02-12T20:03:58Z
dc.abstract.enThe applicability of emission readout of ion-selective electrodes, containing fluorimetrically active polyoctylthiophene in the membrane, operating under chronopotentiometric mode was studied. The electrochemical and optical signals were collected in the same experiment and compared. In both modes a change in recorded signal: potential or emission in time was observed while a constant current was applied to the sensor. The recorded signals (chronopotentiometric, fluoro-chronopotentiometric curves and calculated transition times) were dependent on the concentration of potassium ions. The transition times calculated from electrochemical signals were linearly dependent on the concentration of potassium ions in solution within the range: 0.1–0.7 mM. Optically read transition times were also linearly dependent on concentration within the same range, however, they were shorter than those recorded electrochemically. This difference is attributed to various effects represented by the transition time: concentration increase of reduced form of the conducting polymer in the optical mode or depletion of potassium ions close to the membrane surface, in the electrochemical mode.
dc.affiliationUniwersytet Warszawski
dc.contributor.authorWęgrzyn, Katarzyna
dc.contributor.authorMaksymiuk, Krzysztof
dc.contributor.authorKalisz, Justyna
dc.contributor.authorMichalska-Maksymiuk, Agata
dc.date.accessioned2024-01-25T01:13:58Z
dc.date.available2024-01-25T01:13:58Z
dc.date.issued2021
dc.description.financePublikacja bezkosztowa
dc.description.number21
dc.description.volume8
dc.identifier.doi10.1002/CELC.202100884
dc.identifier.urihttps://repozytorium.uw.edu.pl//handle/item/107306
dc.identifier.weblinkhttps://onlinelibrary.wiley.com/doi/pdf/10.1002/celc.202100884
dc.languageeng
dc.pbn.affiliationchemical sciences
dc.relation.ispartofChemElectroChem
dc.relation.pages4129-4134
dc.rightsClosedAccess
dc.sciencecloudnosend
dc.subject.enchronopotentiometry
dc.subject.enion-selective electrode
dc.subject.enion-transfer voltammetry
dc.subject.enoptical readout
dc.subject.enspectrofluoroelectrochemical sensors
dc.subject.entransition time
dc.titleFluorimetric Readout of Ion Selective Electrode Signals Operating under Chronopotentiometric Conditions
dc.typeJournalArticle
dspace.entity.typePublication