Selective and sensitive electrochemical device for direct VB2 determination in real products

Uproszczony widok
cris.lastimport.scopus2024-02-12T20:13:14Z
dc.abstract.enThe developed by us electrochemical device for vitamin B2 (VB2; riboflavin) determination, without preconcentration step, in real products exhibits high sensitivity, selectivity, stability and low detection limit compared to those described in the literature. The determination procedure was based on the monitoring of the reduction current signal of VB2 bound with dsDNA anchored to the electrode surface through intermediary – carboxyphenyl layer. The application of such intermediary layer formed during electroreduction of appropriate diazonium salt at CV peak potential guarantees high efficiency of hybridization process and thus fully available places for VB2 interaction. Moreover, such intermediary layer provides good electrical contact, what is very important in the case of electrochemical sensors. The analytical range of work of the proposed VB2 sensor was between 0.08–1 µM (30–377 μg L−1) of riboflavin concentration. The obtained detection (LOD) and quantification limits (LOQ) were 24±2 and 55±5 μg L−1, respectively. The proposed VB2 detection method was used for determination of riboflavin content in commercially available dietary supplements and yolk of hen egg samples. The accuracy of the obtained data was proved using comparison with an independent method (HPLC FLD).
dc.affiliationUniwersytet Warszawski
dc.contributor.authorNowicka, Anna
dc.contributor.authorKowalczyk, Agata
dc.contributor.authorKrasnodębska-Ostręga, Beata
dc.contributor.authorSadowska, Monika
dc.date.accessioned2024-01-26T07:30:54Z
dc.date.available2024-01-26T07:30:54Z
dc.date.issued2017
dc.description.financeNie dotyczy
dc.description.volume163
dc.identifier.doi10.1016/J.TALANTA.2016.10.087
dc.identifier.issn0039-9140
dc.identifier.urihttps://repozytorium.uw.edu.pl//handle/item/119550
dc.languageeng
dc.pbn.affiliationchemical sciences
dc.relation.ispartofTalanta
dc.relation.pages72-77
dc.rightsClosedAccess
dc.sciencecloudnosend
dc.subject.enDirect VB2 determination
dc.subject.enSquare wave voltammetry
dc.subject.enDNA biosensor
dc.subject.enDietary supplements
dc.subject.enIntermethod comparison
dc.titleSelective and sensitive electrochemical device for direct VB2 determination in real products
dc.typeJournalArticle
dspace.entity.typePublication