Artykuł w czasopiśmie
Brak miniatury
Licencja

ClosedAccessDostęp zamknięty
 

A comparison study on the use of Dowex 1 and TEVA-resin in determination of 99Tc in environmental and nuclear coolant samples in a SIA system with ICP-MS detection

Uproszczony widok
cris.lastimport.scopus2024-02-12T19:59:27Z
dc.abstract.enThis work refers to a comparative study of sorbents widely used in determinations of 99Tc such as TEVA resin and Dowex 1. Despite having a similar functional group of quaternary amines, both materials represent different chromatographic methods—extraction (TEVA resin) and anion exchange (Dowex 1)—which provides a diverse range of their properties significant in determination of 99Tc in flow conditions. The comparative tests, carried out in a SIA-LOV (Sequential Injection Analysis—Lab-on-Valve) system combined with mass spectrometric (ICP-MS) detection, considered several factors that are crucial from the standpoint of resin´s utility such as sorption capacity, durability, or selectivity, critical in 99Tc separation from interferences. The developed and optimized analytical procedure based on the application of the TEVA resin provided determinations of 99Tc at minimum detectable limit (MDL) 6.00 mBq L-1 in 50 min and has been successfully employed in analyses of samples from nuclear industrial and research units (reactor coolant and sewage) as well as from the river surrounding the nuclear reactor. The method proved to be sufficient for routine analysis of water samples in accordance with EPA standards. The reliability of the method was confirmed in the analysis of the BH standard provided by the NPL for inter-laboratory proficiency tests. The 99Tc recovery for all real samples was evaluated as 80–100%.
dc.affiliationUniwersytet Warszawski
dc.contributor.authorTrojanowicz, Marek
dc.contributor.authorCzajka, Anna Bojanowska -
dc.contributor.authorDudek, Jakub
dc.contributor.authorSamczyński, Zbigniew
dc.contributor.authorKołacińska, Kamila
dc.date.accessioned2024-01-24T17:18:14Z
dc.date.available2024-01-24T17:18:14Z
dc.date.issued2018
dc.description.financeNie dotyczy
dc.description.volume184
dc.identifier.doi10.1016/J.TALANTA.2018.03.034
dc.identifier.issn0039-9140
dc.identifier.urihttps://repozytorium.uw.edu.pl//handle/item/101478
dc.identifier.weblinkhttps://www.sciencedirect.com/science/article/pii/S0039914018302741
dc.languageeng
dc.relation.ispartofTalanta
dc.relation.pages527-536
dc.rightsClosedAccess
dc.sciencecloudnosend
dc.subject.enTc-99
dc.subject.enTEVA resin
dc.subject.enDowex 1
dc.subject.enFlow analysis
dc.subject.enICP-MS
dc.subject.enEnvironmental analysis
dc.subject.enNuclear reactor coolant
dc.titleA comparison study on the use of Dowex 1 and TEVA-resin in determination of 99Tc in environmental and nuclear coolant samples in a SIA system with ICP-MS detection
dc.typeJournalArticle
dspace.entity.typePublication