Occlusion phenomenon of redox probe by protein as a way of voltammetric detection of non-electroactive C-reactive protein

dc.abstract.enSimple, selective and sensitive analytical devices are of a great importance for medical application. Herein, we developed highly selective immunosensor for electrochemical detection of C-reactive protein (CRP) in blood sample. Branched polyethylenimine functionalized with ferrocene residues (PEI-Fc) was the main element of the recognition layer, which allowed: (i) covalent binding of an antibody in its most favorable orientation and (ii) voltammetric detection of the C-reactive protein. Anchoring of PEI-Fc to the electrode surface through the electrodeposition process leads to the formation of thin, stable and reproducible layers, which is extremely important in the case of electrochemical immunosensing. The proposed analytical device is characterized by high selectivity and sensitivity and can be successfully used in the concentration range of CRP from 1 to 5·104 ng mL−1. The determined limit of detection was circa 0.5 and 2.5 ng mL−1 for voltammetric and impedance analysis, respectively. The developed analytical device has also been successfully applied for the analysis of CRP level in rat blood samples.
dc.affiliationUniwersytet Warszawski
dc.contributor.authorGrudziński, Ireneusz
dc.contributor.authorNowicka, Anna
dc.contributor.authorPopławska, Magdalena
dc.contributor.authorKowalczyk, Agata
dc.contributor.authorSęk, Jakub
dc.contributor.authorKasprzak, Artur
dc.date.accessioned2024-01-25T15:13:56Z
dc.date.available2024-01-25T15:13:56Z
dc.date.issued2018
dc.description.financeNie dotyczy
dc.description.volume117
dc.identifier.doi10.1016/J.BIOS.2018.06.019
dc.identifier.issn0956-5663
dc.identifier.urihttps://repozytorium.uw.edu.pl//handle/item/114240
dc.identifier.weblinkhttp://www.journals.elsevier.com/biosensors-and-bioelectronics/
dc.languageeng
dc.pbn.affiliationchemical sciences
dc.relation.ispartofBiosensors and Bioelectronics
dc.relation.pages232-239
dc.rightsClosedAccess
dc.sciencecloudnosend
dc.subject.enC-reactive protein
dc.subject.enOcclusion
dc.subject.enQCM-D analysis
dc.subject.enVoltammetric detection
dc.subject.enImmunosensor
dc.subject.enPolymer network
dc.titleOcclusion phenomenon of redox probe by protein as a way of voltammetric detection of non-electroactive C-reactive protein
dc.typeJournalArticle