Artykuł w czasopiśmie
Brak miniatury
Licencja

ClosedAccessDostęp zamknięty
 

High precision direct analysis of magnesium isotope ratio by ion chromatography/multicollector-ICPMS using wet and dry plasma conditions

Uproszczony widok
cris.lastimport.scopus2024-02-12T19:36:39Z
dc.abstract.enIn this work the applicability of Ion Chromatography (IC) coupled to Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS) for on-line magnesium isotope ratio analysis was explored. Various instrumental setups were employed to enable continuous magnesium separation from the sample matrix by IC followed by MC-ICPMS. The performance of two separation columns IonPac CS16 (ID 5 mm or ID 3 mm) connected with appropriate CERS 500 suppressors (4 mm or 2 mm) using dry and wet plasma conditions was compared. With the use of ID 3 mm column and 2 mm suppressor it was possible to apply dry plasma mode with Aridus II desolvation system. Mass discrimination and instrument drift were corrected by sample-standard bracketing method using the 26Mg/24Mg isotope ratio of DSM-3 as standard. Good accuracy and high precision of the magnesium isotope ratio (generally 0.15‰ (2 SD)) were achieved for wet and dry plasma modes; both were comparable to off-line Mg separation and continuous measurement. The sensitivity of MC-ICPMS measurements with dry plasma was 25 times higher in comparison to wet plasma conditions. Robustness and applicability of the method was demonstrated for matrix-rich natural water and rock samples magnesium isotope analysis.
dc.affiliationUniwersytet Warszawski
dc.contributor.authorWojciechowski, Marcin
dc.contributor.authorBulska, Ewa
dc.contributor.authorKarasiński, Jakub
dc.contributor.authorKrata, Agnieszka
dc.contributor.authorHalicz, Ludwik
dc.date.accessioned2024-01-25T03:28:16Z
dc.date.available2024-01-25T03:28:16Z
dc.date.issued2017
dc.description.financeNie dotyczy
dc.description.volume165
dc.identifier.doi10.1016/J.TALANTA.2016.12.033
dc.identifier.issn0039-9140
dc.identifier.urihttps://repozytorium.uw.edu.pl//handle/item/108508
dc.languageeng
dc.pbn.affiliationchemical sciences
dc.relation.ispartofTalanta
dc.relation.pages64-68
dc.rightsClosedAccess
dc.sciencecloudnosend
dc.subject.enMC-ICPMS
dc.subject.enWet and dry plasma mode
dc.subject.enIsotope ratio
dc.subject.enMagnesium
dc.subject.enIon chromatography
dc.titleHigh precision direct analysis of magnesium isotope ratio by ion chromatography/multicollector-ICPMS using wet and dry plasma conditions
dc.typeJournalArticle
dspace.entity.typePublication